VasioCore® health
Longevity check-up for heart & vessels
VasioCore® health is a non-medical product; classification as a Class IIa medical device is aimed for mid-2027.
VasioCore® complements the physician's assessment by analysing the shapes of the pulse pressure signals and making central cardiovascular properties visible by means of innovative, AI-based methods.
Drawn pulse wave of three heartbeats, the middle one highlighted: steep rise, peak, small notch, slow decline. No values.
About 12 minutes
Examination time
Source
Home page of the previous inmediQ website (“in about 12 minutes of examination time”), as of 7 November 2026. Other passages say about 10 minutes; confirmation by inmediQ pending.
Six leads
VasioCorder® records pulse curves over six leads in high resolution.
Source
Brochure “VasioCore® health”, V2, 17 August 2026, shortened. Approval pending.
Easy to delegate
The optimised workflow keeps staff effort low.
Source
Brochure “VasioCore® health”, V2, 17 August 2026. Approval pending.
PDF report
The analysis results are prepared in a structured PDF report.
Source
Offer “VasioCore® health”, undated. Approval pending.
Where VasioCore® is used
For physicians
Changes appear not merely as abstract measured values, but as a comprehensible interpretation of central cardiovascular properties.
For longevity facilities and studios
The effects of training, lifestyle changes […] on the cardiovascular system become transparent and traceable.
From the pulse wave to the digital health picture
How VasioCore® works
The measurement is carried out non-invasively using cuffs at defined measuring points. The patient lies still during the measurement. The measuring procedure can be delegated and runs automatically.
Source
Information sheet “VasioCore® Longevity Check-up für Herz & Gefäße” (physicians' version), section “Praktische Durchführung” (practical procedure), undated. Approval pending.
Four stages: 1. Six measuring points, a line leaves each one. 2. The six lines record even pulse waves. 3. The six lines run together into one. 4. One pulse wave sits in a report. No values.
Apply the cuffs
Cuffs are placed on the upper arms, wrists and ankles – comfortable & painless.
Measure the signals
High-resolution pulse pressure biosignals are recorded in about 12 minutes.
The AI creates your twin
Our model simulates 711 arterial measurement points of your cardiovascular system.
See the results live
You receive your individual analysis: vascular age, arterial elasticity, flow resistance, blood flow properties, cardiac status.
What does VasioCore® show?
The result is a structured VasioCore® report that summarises essential performance and prevention parameters of the heart and vessels and serves as a basis for the medical consultation.
Source
Information sheet “VasioCore® Longevity Check-up für Herz & Gefäße” (physicians' version), undated. Approval pending.
Three central vascular parameters
VasioCore® compares calendar age with the functional condition of the vessels. Three central vascular parameters are assessed:
- Vascular stiffness
- Flow resistance
- Blood mass inertia
Vascular age and age-related orientation
A particular benefit of VasioCore® lies in presenting individual measurement results in relation to age-related reference curves. This turns a technical measured value into an orientation that patients can understand.
Source
Physicians' version, section “Gefäßalter und altersbezogene Orientierung” (vascular age and age-related orientation), shortened. Approval pending.
Placeholder: sample report from inmediQ missing
A page of the VasioCore® report with sample data will appear here once inmediQ provides it.
Literature / sources
Evidence and studies
Schumacher G, Kaden JJ, Trinkmann F. Multiple coupled resonances in the human vascular tree: refining the Westerhof model of the arterial system. J Appl Physiol 2018; 124: 131–139. doi:10.1152/japplphysiol.00405.2017
Relates to: the method, not VasioCore®
Massmann A et al. Automated oscillometric blood pressure and pulse-wave acquisition for evaluation of vascular stiffness in atherosclerosis. Clin Res Cardiol 2017; 106: 514–524. doi:10.1007/s00392-017-1080-7
Relates to: the method and predecessor devices, not VasioCore®
Trinkmann F et al. Automated Noninvasive Central Blood Pressure Measurements by Oscillometric Radial Pulse Wave Analysis: Results of the MEASURE-cBP Validation Studies. Am J Hypertens 2021; 34: 383–392. doi:10.1093/ajh/hpaa174
Relates to: the method and predecessor devices, not VasioCore®
Specialist article, January 2026
The specialist article by Dr. rer. nat. Reinhard Merz, published in Der Privatarzt – Medizin & Management (January 2026), focuses on the significance of the Cardiovascular Twin in the context of modern preventive medicine.
Source
Home page of the previous inmediQ website, as of 7 November 2026. The article itself is published by the journal (in German); scope of the e-licence open.
What the measurement does not say
Draft
The heading, point 3 and point 4 are not verbatim from inmediQ material. Points 1 and 2: brochure “VasioCore® health”, V2, 17 August 2026, and physicians' version. English translation not yet approved by inmediQ.
- VasioCore® is currently not a medical device but a system for health optimisation and longevity.
- VasioCore® complements the physician's assessment. To what extent the data of the Cardiovascular Twin can be transferred to subjects or patients is judged by our users in accordance with our intended purpose and on their own professional responsibility.
- Vascular age is an age-related orientation in relation to reference curves.
- The publications concern the method and the predecessor devices VascAssist and VascAssist 2, not VasioCore® itself.
Two ways to the system
Connect
VasioCore® health Connect
The VasioCorder® system remains the property of inmediQ GmbH and is provided for the contractually agreed period of use.
- Provision of a VasioCorder® for individual use
- Software extensions and support packages
- Maintenance every 2 years (device and accessories) during the active term of the VasioCore® Twin platform licence
Your advantage: no device purchase, predictable running costs and regular maintenance as part of the Connect service.
Own
VasioCore® health Own
The VasioCorder® becomes the customer's property once the purchase price has been paid in full. Financing through leasing partners is possible on request.
- Purchase of a VasioCorder® for individual use
- Optionally bookable: software extensions and support packages
- Optional: maintenance every 2 years (device and accessories) as a separately charged service
Your advantage: permanent ownership of the device, with the Twin platform used as needed within the chosen licence.
Included in both variants
- Setup and activation of access to the VasioCore® Twin platform
- Commissioning and system configuration
- Online training in the use of the system and the Twin platform
- On-site training possible by arrangement/effort
For both VasioCore® health Connect and VasioCore® health Own, an active Twin platform licence with a minimum term of 12 months is required.
Source
Offer “VasioCore® health”, section “3. VasioCore® Twin-Plattform-Lizenz” (Twin platform licence), undated. Approval pending, including whether the structure of the offer may be published.
Available licence models:
- Up to 50 automated Twin analyses including PDF report per month
- Up to 100 automated Twin analyses including PDF report per month
Calculator with your figures
Enter your own values. The calculation runs in the browser, nothing is sent, the formula is shown alongside.
Draft
Text not from inmediQ material (Konzept 1.5, S4). Legal review before going live. Approval pending.
“Placeholder: voice of a practice that uses VasioCore®. Reference from inmediQ missing.”
Placeholder: name, practice, town
Video demo (Teams)